              Anesthesia Equipments & Accessories Type Datex Ohmeda Anesthesia MachineAnesthesia SystemModel:MCA-302 Main Feature of Anesthesia Machine:1. Applied for closed, semi-closed, semi-openinhalation anesthesia, controlled orassisted ventila......

              Send Inquiry

              Product Description

              Anesthesia Equipments & Accessories Type Datex Ohmeda Anesthesia Machine

              Anesthesia System
              Model:MCA-302

               Main Feature of Anesthesia Machine:
              1. Applied for closed, semi-closed, semi-open
              inhalation anesthesia, controlled or
              assisted ventilation, monitoring and
              display patients' ventilation parameters
               
              2. Applied for adult and pediatric
               
              3. Integrated anesthetic ventilation system,
              APL security air relief valve is available
               
              4. Vaporizers: 2.  Advanced temperature,
              flow and pressure compensation technology,
              Isofurane, Enfurance, Halothane and
              Sevoflurance as per option
               
              5. 8.4" TFT-LCD display screen
               
              Main Specification of Ohmeda Anesthesia Machine:
              Type: Electronically controlled, Pneumatic driven
              Patient spectrum: Pediatric to bariatric
               
              Mode of Equipments & Accessories Type manual ane: VCN, SIGH, SIMV, Stand-by, Manual, PEEP
              Hypoxic guard system: N2O cut-off valve, O2 concentration no less than 25%
              Safety valve: <12.5kpa
               
              Monitoring of Anesthesia Equipments & Accessories: VT, MV, BPM, Paw, FiO2, Lung compliance
              Waveform: Pressure-time, flow-time, pressure-volume loop, volume-time (Optional), flow-volume loop (Optional)
              Power: AC 220V±10%, 50Hz±2%, built-in battery support
               
              Gas: O2, N2O, air
               
              Alarm: Optimal multi-class alarm unit, VT beyond limitation, upper and lower limitation of ventilation, upper  and lower limitation of ventilation, upper and lower limitation of airway pressure, asphyxiation, current failure, gas source hypotonic, gas circuit abnormity, upper and lower limitation of CO2 concentration (Optional)
               
              Prompt and protection: Prompt for parameter limitations, protection for unreasonable parameter setting.
               

               