Home > Products > Surgical Equipment > Ce Mark Medical Surgical Anesthesia Ventilator Machine Price
              Ce Mark Medical Surgical Anesthesia Ventilator Machine Price
              • Ce Mark Medical Surgical Anesthesia Ventilator Machine PriceCe Mark Medical Surgical Anesthesia Ventilator Machine Price
              • Ce Mark Medical Surgical Anesthesia Ventilator Machine PriceCe Mark Medical Surgical Anesthesia Ventilator Machine Price
              • Ce Mark Medical Surgical Anesthesia Ventilator Machine PriceCe Mark Medical Surgical Anesthesia Ventilator Machine Price
              • Ce Mark Medical Surgical Anesthesia Ventilator Machine PriceCe Mark Medical Surgical Anesthesia Ventilator Machine Price

              Ce Mark Medical Surgical Anesthesia Ventilator Machine Price

              Features:1. Pneumatically driven electronically controlled system2. Built-in ventilator, LED display screen3. With 1 patient circuit for adult (Option: patient circuit for children).4. 4-tube flowm......

              Send Inquiry

              Product Description

              Features:
              1. Pneumatically driven electronically controlled system
              2. Built-in ventilator, LED display screen
              3. With 1 patient circuit for adult (Option: patient circuit for children).
              4. 4-tube flowmeters, O2 & N2O;0.1 L/Min ~ 10 L/Min;
              5. Vaporizer: Enflurane / Isoflurane / Sevoflurane;
              (Option: Halothane)
              6. Ptr:-10~10hPa;
              7. Respiration Mode: IPPV, SIPPV, Manu
              8. Tidal Volume: 50~1500mL;
              9. Respiration Frequency: 4~40bpm;
              10. I/E Ratio: 1:1.5~1:3

              Prospective service and support
              This HA-3200A Anesthesia Machine is an essential important anesthesia device in an operation room. Its function is to provide oxygen and anesthetic agent to a patient needing to go through an anesthesia operation and perform ventilation management.
              A highly efficient and large volume soda lime absorber can minimize the re-inhalation of carbon dioxide by the patient.
               
              TECHNIQUES SPECIFICATIONS
              Physical specifications
              ScreenLED Display Screen
              SuitableAdult & Child
              Modepneumatically powered and electrically controlled system
              Working ModeClosed; Semi-Closed; Semi-Open
              CircuitBreathing circuit integrated standards
              Tube2 Tubes Flowmeters:  O2:0.1~10L/Min,  N2O:0.1~10L/Min
              TrolleyFitted with 4 nos anti-static rubber castors; two of which are lockable for braking and easy maneuverability with foot operated brake provisions
              Drawer unitONE drawer totally extractable

              Technical Specifications:

              Gas requirement

              Medical oxygen and nitrous oxide with a pressure ranging from
              O2: 0.32~0.6MPa ;   NO2: 0.32 MPa to 0.6 MPa.

              Safety valve

              <12.5  kPa

              Respiratory Rate

              4~40bpm

              Flow meter

              O2:0.1~10L/Min,  N2O:0.1~10L/Min

              Oxygen concentration in the mixed gas N2O/O2

              > 21%

              Oxygen Flush:

              25~75 L/min

              Maximum error of the pressure testing device

              not exceed ± (4% of the full scale reading + 8% of the actual reading)

              modes of ventilation

              A/C,IPPV, SIPPV, MANUAL

              I/E Ratio

              1:1.5; 1:2.0;1:2.5; 1:3

              Tidal Volume

              0~1500ML

              Controlled ventilation and assisted ventilation switching time

              6s

              Maximum safety pressure

              ≤ 12.5 kPa

              Pressure limit range

              0 ~ 6.0  kPa

              Airway pressure alarm: Audible and visual and with yellow and red color indicating

              Lower: 0.2kPa~5.0kPa;   Upper: 0.3~6.0  kPa

              ±0.2 kPa

              Tidal volume alarm: Audible and visual and with yellow and red color indicating

              upper alarm: 50 to 2000ml,lower alarm: 0~1800ml

              Power Supply Alarm

              Ac/dc power supply are after failing to send out alarm immediately
              Alarm Time: keep >120s

              Operating conditions

              Ambient temperature

              10 ~ 40oC

              Relative humidity

              no higher than 80 %

              Atmospheric pressure

              860 hPa ~ 1060 hPa

              Power requirement:

              100-120 Vac, 50/60 Hz; 

              Air source requirement

              Medical oxygen and laughing gas with a rated pressure ranging from 0.3 to 0.5MPa.

              Attention: the AC power supply used for the anesthesia machine must be well   grounded.

              Attention: the anesthesia machine used must be equipped with a carbon dioxide monitor complying with ISO 9918:1993, an oxygen monitor complying with ISO 7767:1997 and an expiratory gas volume monitor complying with 51.101.4.2 of Medical Electrical Equipment Part II: Special Requirements for Safety and Basic Performance of Anesthesia System.

              Configuration:

              Vaporizer

              Enflurane/ Isoflurane(Option: Halothane)

              Storage

              Ambient temperature

              -15oC ~ +50oC

              Relative humidity

              no higher than 95 %

              Atmospheric pressure

              86 kPa ~ 106 kPa.

              It should be stored in a room without corrosive gas and well ventilated

              Package

              packaging box

              comply with the requirement of GB/T 15464
               
              Between the packaging box and product, soft material with appropriate thickness provided to prevent loosening and mutual friction during transportation
               
              Moisture protection and rain protection to ensure that product is protected from natural damage.

              Safety & Alarm

              Oxygen Alarm

              It alarms when the oxygen  supply from pipe or cylinders lower than 0.2MPa

              Ventilation Volume Alarm

              Lower: 0~12L/Min;
              Up: 18L/ Min

              Power Alarm

              It Alrmas while AC and DC supply failure ; Keep alraming  time: >120s