              Servocuna Resuscitaire Neonatal Infant Radiant Warmer with X-ray Cassete
              • Servocuna Resuscitaire Neonatal Infant Radiant Warmer with X-ray CasseteServocuna Resuscitaire Neonatal Infant Radiant Warmer with X-ray Cassete

              Servocuna Resuscitaire Neonatal Infant Radiant Warmer with X-ray Cassete

              Servocuna Resuscitaire Neonatal Infant Radiant Warmer With X-ray CasseteBrief Introduction:Three control modes: Pre-warm mode control, manual mode control and baby mode control by micro-computer;Set temperature and baby temperature can be displayed separately&a......

              Send Inquiry

              Product Description

              Servocuna Resuscitaire Neonatal Infant Radiant Warmer With X-ray Cassete

              Brief Introduction:
              Three control modes: Pre-warm mode control, manual mode control and baby mode control by micro-computer;
              Set temperature and baby temperature can be displayed separately;
              Horizon angle of warmer module and inclination of the bassinet can be adjusted;
              The panels around bassinet can be turned outward;
              X-ray cassette under the bassinet;
              APGAR timer;
              Timer to count phototherapy time;
              Failure alarm indication;
              RS232 connector.

              Standard Configuration:
              IRW-9300: warmer module, bassinet, main column, mobile stand, controller, I.V. Pole and tray.
              IRW-9300B: based on IRW-9300, added with the phototherapy unit.
              IRW-9300A: based on IRW-9300B, added with the breath resuscitation bag, infant head fixing unit, the oxygen supplying set ( the oxygen cylinders, buoy type oxygen regulator, wall type oxygen regulator),low-pressure suction.

              Optional Configuration:
              Disposable skin temperature sensor, Vertical height adjustment (VHA) stand and Weighing system

              Specification:
              Power requirement: AC220V-230V/50Hz or AC110-120V/50-60Hz, 700VA (IRW-9300)
                                 AC220V-230V/50Hz or AC110-120V/50-60Hz, 750VA (IRW-900B,IRW-9300A)
              Mode of control: Pre-warm mode, manual mode and baby mode are controlled by micro-computer
              Baby mode temperature control range: 34.5-37.5ºC
              Skin temperature display range: 5ºC-65ºC
              Accuracy of skin temperature sensor:  ±0.2ºC
              Temperature uniformity of mattress:   ≤2ºC
              Angle of heater head: 0°,30°,60° for two ways
              Inclination of the bassinet: ±10°
              APGAR timer: audible and visible  alarm when the device runs to 50″~1′,4′50″~5′,9′50″~10′;
              Failure alarm: over temperature alarm, deviation alarm, sensor failure alarm, power failure alarm, setting alarm, checking alarm and so on.
              The total irradiance Ebi on the effective surface area: ≥0.66mW/cm2 (IRW-900B,IRW-9300A)
              Average value of general bilirubin radiation on the mattress effective range: ≥0.58mW/cm2 (IRW-900B,IRW-9300A)
              Bilirubin uniformity of radiating on the mattress effective range: >0.4(IRW-900B,IRW-9300A)
              Dominant wavelength of blue light: 400-550nm
               